					Data Sheet | 
					FNP-LED (MIMIC LED Display) 
					STANDARD FEATURES:• Available in Red and Charcoal Gray • Up to 504 LED's can be controlled with FireNET Plus Panel
 • Available in 3 different size enclosures
 • LED's comes in 3 different colors: Red, Green, or Yellow
 • FNP-LED can be easily upgraded onsite with minimal cost and effort
 | 
		
			| 
					 
					Data Sheet
 | 
					FN-LCD-N (Network Annunciator) 
					STANDARD FEATURES:• UL 864 9th edition approved • 320 character liquid crystal display (8 line x 40 character)
 • Dual RS-485 ports for primary fire network
 • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
 • True Peer-to-Peer network annunciation
 | 
		
			| 
					 
					Data Sheet | 
					FN-LCD-S (Serial Annunciator) 
					STANDARD FEATURES: 
					• UL 864 9th edition approved• Large 320 character liquid crystal display (8 line x 40 character)
 • Resides on the FireNET slave RS-485 lin
 
					  | 
		
			| 
					 
					Data Sheet | 
					FN-ACC-R/C (Battery/Accessories Enclousure) 
					STANDARD FEATURES:• Designed to provide a method to properly store backup batteries for the FireNET and FireNET Plus panels • The enclosure can also be used to mount 16 Channel I/O Boards
 • The battery enclosure comes in two colors Red (FN-ACC-R) & Charcoal (FN-ACC-C), and comes with a keylock
 
					  
					  | 
		
			| 
					 
					Data Sheet 
					Instruction | 
					TCF-142-M-ST (Fibre Optic Module) 
					STANDARD FEATURES:• Capability to network FireNET™, FireNET Plus, and Network Annunciator using fiber optic cables • Extends RS-485 transmission up to 3.1 miles
 • Protects against electrical interface and chemical corrosion
 • No special programming required
 • UL 864 9th Edition Liste
 | 
		
			| 
					 
					Data Sheet | 
					FN-4127-SLC (Dual Loop Expander Card for FireNet) 
					STANDARD FEATURES:• Adds two SLC loops to a two loop FireNET control panel • Each SLC loop is capable of 127 sensors/modules, plus 127 analog sounder bases, for a potential total of 254 addresses per loop (127+127 per loop)
 • FN-4127-SLC can be added at the factory or installed in the field
 • Supports Class A and B wiring methods per NFPA72 Styles 4, 6, and 7 (with isolators)
 • Fully supervised & power limited SLC loops
 • Supports Hochiki's DCP (Digital. Communication Protocol) loop protocol
 • Same functionality as built-in SLC loops of FireNET control panel
 • One SLC expander (maximum) may be added per FireNET control panel
 • Each SLC loop is completely independent and autonomous
 • Uses standard wire, no shielded or twisted pair required on SLC loop
 | 
		
			| 
					 
					Data Sheet | 
					FNP-1127-SLC (Single Loop Expander Card for FireNet Plus) 
					STANDARD FEATURES:• Adds one SLC loop to the FireNET Plus (FNP-1127E series) control panel • The SLC loop is capable of 127 sensors/modules, plus 127 analog sounder bases, for a potential total of 254 addresses
 • The FireNET Plus 1127E control panel supports one FNP-1127-SLC, for a total of two SLC loops per panel
 • Supports Class A and B wiring methods per NFPA 72 Styles 4, 6, and 7 (Style 7 requires isolators)
 • Fully supervised & power limited SLC loop
 • Supports Hochiki's DCP (Digital Communication Protocol)
 • Same functionality as built-in loop of FireNET Plus control panel
 • Uses standard wire; shielded/twisted pair is not required on SLC loops
 | 
		
			| 
					 
					Data Sheet | 
					FN-4127-NIC (Dual RS-485 Network Interface Card) 
					STANDARD FEATURES:• Allows for the expansion of up to 64 panels on a FireNET system • Enables information to be transmitted between control panels
 • Network protocol designed for tolerance to interference and data corruption
 • Each card configured to a unique address through use of a dipswitch
 • Transmission distance of up to 4,000 ft.
 • Uses standard type Belden cable suitable for RS-485 applications
 • Simple 2-wire loop connection
 • Flexible configuration options
 • Network wide Cause & Effect logic
 • Fully secure against short or open conditions
 | 
		
			| 
					 
					Data Sheet | 
					FN-4127-IO (16 Channel Input/Output Board) 
					STANDARD FEATURES:• 16 channels of input/output points • 32 I/O boards per FireNET panel (512 channels of input/output points)
 • Each channel configurable as input or output point
 • Inputs are opto-isolated non-supervised pulldown type triggered by
 • Outputs are open collector transistor pulldown type (100mA max each) that provide
 • Simple 4 wire connection to control panel (2 for power, 2 for data)
 • All inputs/outputs can be assigned to global functions, any event category, and used in network wide Cause & Effect logic
 • Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4000ft from the panel
 • Each I/O board has a unique address 1-32 (set via DIP switch) on the I/O Comms Bus
 • Input/Outputs are for secondary use, not for primary fire initiation inputs or notification outputs
 • Two LED's are provided for communication status
 | 
		
			| 
					 
					Data Sheet | 
					GUS Series (FireNET Graphix Alarm Management Software) 
					STANDARD FEATURES:• Choice of text, graphic and event list display when event occurs • Versatile event analysis
 • Total history archive
 • Easy to program
 • Secure system
 • Cost effective compared to other systems
 • Simple to use
 • Unlimited map linking
 • Display and control for multiple panels